ESS-05 Datasheet
Download
CANBUS/RS485/RS232 protocol compatible
| Stored energy | 5.120kWh |
| Rated capacity | 100Ah |
| Nominal voltage | 51.2V |
| Volt range | 43.2V-57.6V |
| Charge time | Standard2.2h |
| Rapid1.5h | |
| Charge method CC-CV | Standard50A/56V |
| Rapid100A/56V | |
| Surge(10S) 120A(10S) | |
| Max discharge current | Continous 100A |
| Cycle life 0.5C, 23℃/73°F | 80% >7000 cycles |
| Operating temperature range | Charge 0°C~60°C/32°F~140°F |
| Discharge -20°C~60°C/-4°F~140°F | |
| Storage(1month) -20°C~45°C/-4°F~113°F | |
| Storage(6month) 0°C~35°C/32°F~95°F | |
| Communication port | RS232/RS485/CAN |
| Approx weight | 52kg /115lbs |
| Series & parallel connection | Max 16 batteriesin parallel connection.Series connection is not available. |
| Length | Width | Width |
| 390mm | 160mm | 590mm |
| 15in | 6.3in | 23.2in |
| Balance | Current | 30mA |
| Activate volt | >3.55V/ cell &cell Voltage difference>30mV | |
| High temperature protection(MOSFET) | Protection | 115°C/239°F |
| Alarm | 90℃/194℉ | |
| Release | 85°C/185°F | |
| High temperature protection(cell) | Protection | 65°C/149°F(charge) |
| 70°C/158°F(discharge) | ||
| Alarm | 60°C/140°F(charge) | |
| 65°C/149°F(discharge) | ||
| Release | 55°C/131°F(charge) | |
| 60°C/140°F(discharge) | ||
| Low temperature protection(cell) | Protection | 0°C/32°F(charge) |
| -20°C/-4°F(discharge) | ||
| Alarm | 5°C/41°F(charge) | |
| -15°C/5°F(charge) | ||
| Release | 5°C/41°F(charge) | |
| -15°C/5°F(discharge) | ||
| Heating (option) | Activate | Temp≤5°C &Charge current≥4A |
| Release | Temp>15°C &Charge current <4A | |
| Over-charge | Protection | 59.2V(3.7V/cell) |
| Alarm | 57.6V(3.6V/cell) | |
| Release | 54.08V(3.38V/cell) or SOC<96% | |
| Over-discharge | Protection | 43.2V(2.7V/cell) |
| Alarm | 44.8V(2.8V/cell) | |
| Release | 47.2V(2.95V/cell) or charge the battery | |
| Primary over- current | Protection | 130A(1S) |
| Alarm | 125A | |
| Release | Automatic release after 60S | |
Secondary over-current | Protection | 180A(0.5S) |
| Release | Automatic release after 60S | |
| Short-circuit | Protection | Yes |
| Release | Remove load or charge the battery | |
| Lose Efficacy | Activate | cell Voltage difference>1V (battery can't charge & discharge ) |
| BMS record | Capacity | ≥1000 records |
| Length | Width | Width |
| 390mm | 160mm | 590mm |
| 15in | 6.3in | 23.2in |
Real-time communication between BMS and inverter realizes dynamic voltage and current adjustment, eliminating overcharge and overheating risks.
Supports remote battery status and power consumption checking via mobile phones and computers for convenient household energy management.
Built-in heater activates automatically below 0℃ (charging current ≥5A), maintaining constant 20℃ working temperature for stable operation in severe winter.